Implementation and support

Pilots, integration and service

Latest

Pilots

Clinical studies of a device that has not been cleared or approved run under an Investigational Device Exemption (IDE, 21 CFR Part 812). An IDE allows the investigational device to be used in a clinical study to collect safety and effectiveness data. The study needs an investigational plan approved by an institutional review board (IRB) and informed consent from all patients; if the study involves a significant risk device, the IDE must also be approved by FDA.

FDA also runs the Technology-Enabled Meaningful Patient Outcomes (TEMPO) for Digital Health Devices Pilot in connection with the ACCESS model of the Centers for Medicare & Medicaid Services (CMS) Innovation Center. A manufacturer in the pilot may request that FDA exercise enforcement discretion for certain requirements while it collects real-world data, in four clinical use areas: early cardio-kidney-metabolic, cardio-kidney-metabolic, musculoskeletal and behavioral health. FDA expects to select up to about ten manufacturers per area, and manufacturers must be based in the United States.

System integration

The Office of the National Coordinator for Health Information Technology (ONC) runs the ONC Health IT Certification Program. Under the HTI-1 Final Rule, the United States Core Data for Interoperability (USCDI) Version 3 is the baseline standard in the Certification Program as of January 1, 2026. The certification criterion § 170.315(g)(10), Standardized API for patient and population services, is based on HL7 FHIR Release 4.0.1, the HL7 FHIR US Core Implementation Guide STU 6.1.0, the HL7 SMART App Launch Implementation Guide Release 2.0.0 and FHIR Bulk Data Access.

The HTI-5 Final Rule (overview dated October 26, 2026) removed 14 and revised seven of the Certification Program's 60 certification criteria; ONC states that it establishes a new foundation on which to build FHIR-based API requirements. According to the Federal Register, the rule is effective on December 28, 2026, except for amendatory instructions 7, 10 and 12, which are effective on January 1, 2027.

The Trusted Exchange Framework and Common Agreement (TEFCA) operates as a nationwide framework for health information sharing. Qualified Health Information Networks (QHINs) are the individual networks that form its backbone; a QHIN must be a U.S. entity. The Sequoia Project serves as the Recognized Coordinating Entity (RCE) under a five-year contract with ONC awarded in August 2023.

Local service and maintenance

FDA defines servicing as the repair and/or preventive or routine maintenance of one or more parts in a finished device, after distribution. Remanufacturing is the processing, conditioning, renovating, repackaging, restoring, or any other act done to a finished device that significantly changes its performance or safety specifications or intended use. FDA looks at the specific activities an entity performs on a particular device. Entities engaged in remanufacturing are subject to requirements including registration and listing, adverse event reporting, the QMSR and marketing submissions.

For imported devices, the initial importer must maintain an MDR event file for each adverse event, and all product complaints, MDR and non-MDR events alike, must be forwarded to the manufacturer.

Sources

  1. FDA – Investigational Device Exemption (IDE) · verified
  2. FDA – TEMPO for Digital Health Devices Pilot · verified
  3. ONC – HTI-1 Final Rule · verified
  4. ONC Health IT Certification Program – § 170.315(g)(10) Standardized API for patient and population services · verified
  5. ONC – HTI-5 Final Rule Overview · verified
  6. Federal Register – Health Data, Technology, and Interoperability: ONC Deregulatory Actions To Unleash Prosperity (91 FR 67916, document 2026-21943) · verified
  7. ONC – Advancing Nationwide Interoperability with TEFCA · verified
  8. FDA – Remanufacturing and Servicing Medical Devices · verified
  9. FDA – Importing Medical Devices and Radiation-Emitting Electronic Products into the U.S. · verified

Updated